1x3 Fused PM Fiber Broadband Splitter | |||
Product Features | Product Applications | ||
|
|
||
|
|
||
|
|
||
|
|
||
Telcordia GR-1221 Compliant Test |
Specifications | Splitting Ratio: 33:33:33 | |||
Parameter | Unit | Premium | A grade | |
Port Configuration | 1x3 | |||
Central Wavelength | nm | 1310, 1480, 1550, 2000 | ||
Bandwidth | nm | ±30 | ||
Excess Loss | Typ | dB | 0.3 | 0.5 |
Excess Loss | Max | dB | 0.6 | 0.8 |
Polarization Extinction Ratio | Min | dB | 18 | 16 |
Splitting Ratio Tolerance | Max | % | ±8 | ±10 |
Operating Power | Max | W | 2 | |
Operating Temperature | °C | -40 to +85 | ||
Storage Temperature | °C | -50 to +85 | ||
Package Type | mm | S6=Ø3x54 / S12=Ø4x70 / M2=7.5x18x90 |
Above PER is for more than 10%(CR) port, it's 2dB lower for no more than 10%(CR) port, and 4dB lower for no more than 5%(CR) port.
All specifications are before connectors. PER is 2dB lower and EL is 0.2dB higher after connectors.
Ordering Information | ||||||||||||
P | M | B | S | |||||||||
Wavelength 4=1550nm 5=1480nm 7=1310nm P=2000nm S=Specify |
Structure 3=1x3 |
Splitting Ratio 33=33:33:33 |
Grade P=Premium A=A grade |
Package 5=S6 with 250μm bare fiber pigtail B=S12 with 0.9mm loose tube E=M2 with 3mm cable |
Fiber Type E=Panda fiber |
Fiber Length 0=0.5m 1=0.75m 2=1.0m 3=1.5m 4=2.0m S=Specify |
Connector 0=None 1=FC/PC 2=FC/SPC 3=FC/APC 7=FC/UPC |
Note: 1. Central wavelength can be customized for different applications.
2. All specifications are subject to change without notice.
3. All data are measured at central wavelength at room temperature.